Follow us
Get in touch!

Unit 6 Stoneacre
St James Retail Park
Grimbald Crag Close
Knaresborough
HG5 8PJ

FRIWO | UK

Battery Pack and Charger Selection for Optimum Performance

Ben Winstanley • May 12, 2021

Selection and operation of a battery charger

Optimum performance of batteries should be an important consideration in the design of any battery powered product, and while it is often the case that larger or ‘better’ batteries are adopted to meet the technical requirements, less thought is typically given to the ongoing management of batteries in the field.


In this article we will consider some of the most relevant factors impacting on whether the product lasts for years, or ends up in landfill (or hopefully recycling) within 24 months of manufacture.


For all the commonly used chemistries there are a large selection of manufacturers offering a wide range of cells at, often, significantly differing price points to meet a range of different product specifications. While it is well understood that an industrial cell from a branded manufacturer will have better overall performance that a lower cost product designed for the consumer market, there are a number of factors external to the cell construction and quality that can have an equally important effect upon cell life...


For example: the match between the battery pack and the charger.

Battery Pack and Charger Match

Charger and Battery Matching Up Visual - Created by Haredata Electronics


Lead Acid (Pb) Battery Packs

For Lead acid batteries the impact is less significant, Lead Acid batteries are more tolerant of abuse such as overcharging, and are more able to cope with significant changes in the required load without a massive impact on cycle life (as long as the correct standard of battery has been selected) However, it is still possible to overcharge a sealed Lead Acid Battery, and because the resultant excess gas cannot escape this can lead to batteries ‘bulging’ in a most alarming way!


Because of their high weight and low cost, Lead Acid batteries are still a good option for heavy industrial applications when charging time is less of a factor, and ‘taper’ chargers at a low current wrt to capacity are often adopted. These offer the advantage of steadily bringing the cell voltage up to 2V but can remain connected indefinitely as the current is typically less than 0.1C (where C is the battery capacity) and so the battery can safely lose the excess energy once fully charged (as heat). The downsides are slower charging and an inefficient use of power.

Nickel–metal Hydride (NiMH) & Lithium Ion (Li-Ion) Battery Packs

Of course for most battery powered equipment the desire is to have a small, lightweight battery than can be charged very quickly and then power the product for hours and hours. NimH batteries do have many advantages over Lead Acid, but the main chemistry adopted for such products is Li-Ion. The 2 chemistries share several properties in terms of their charging and discharging profile, so we’ll consider them together below...


Typically these batteries can be designed to offer high discharge current, large initial capacity, or long cycle life (or a degree of compromise between all 3) Therefore quantifying exactly how the product is expected to be used helps inform the decision on cell selection and in turn a suitable charger. Battery cycle life is impacted by charge and discharge rates, so for a low discharge application the biggest determinant of the battery life is the charge rate and control of charge termination to prevent overcharge. If the rate of discharge is high, then a slow rate of charge to look after the batteries will have proportionally less effect, as the cells have already been thoroughly worked over.


In either case overcharging must be avoided at all costs, a small degree of overcharging will gently ‘cook’ the batteries (NimH and Li-Ion are much less happy being heated up than Lead Acid) and significant overcharge can lead to structural failure of the cell (explosively in the case of Li-Ion) The desired objective therefore is a charger that will charge the batteries quickly (but not too quickly) make sure they are fully charged (but not overcharged) and ‘manage’ the cells during the process – i.e. is able to detect any issues and modify the charging profile according to the state of the battery.

Battery Pack and Charger Match

Cooking NiMH Batteries Visual - Created by Haredata Electronics


NimH and Li-Ion Battery Chargers | Voltage Sensing & Temperature Sensing

The whole range of NimH and Li-Ion chargers manufactured by FRIWO are able to detect the number of cells in the battery pack once connected, and supply the correct charging voltage/current accordingly. If the voltage of a battery is not within a safe ‘charge window’ – for example because it has been left for an extended period and the cell voltage has dropped too low, then a lower pre-charge current is applied to gently ‘wake’ the battery up before the full charge current is delivered (only as and when the voltage has risen to the pre-determined level).


Due to this voltage sensing technology the charger is also able to recognise the characteristic ‘dip’ that occurs as the cells approach full charge, and is then able to reduce the current to a float charge level to top up the last few percent of capacity without risking overcharge. All of these stages are communicated via the LEDs on the top of the battery charger, so the end user can understand the status of the battery at glance.


Voltage sensing can be operated via any standard 2 pole connector, and requires no additional componentry to be added to the battery pack. Another method that can be operated instead or alongside voltage detection is temperature sensing. In order for the FRIWO battery charger to be able to read the temperature of the battery pack a temperature variable resistor (thermistor) needs to be added ideally somewhere near the middle of the pack. The charger then connects via a 3 wire connection (meaning standard jack plugs cannot support this technology). 


There are 2 main advantages of temperature sensing – because the charger can tell how hot the pack is, it can decline to charge it if it would result in damage to the battery – this typically occurs if a battery pack has been left in a very high or low ambient temperature prior to charge (e-bike batteries left in a garage in the middle of winter spring to mind) or if it has just been discharged at a high rate and is then plugged straight into the charger (a typical power tool situation) The charger will indicate a temperature warning, and wait for the pack to cool down/warm up before commencing the main charge.


As a battery pack ages the individual cells in the pack can degrade at different rates (this is partly dependent upon the level of cell balancing within the battery management system, if fitted) This can result in the voltage dip becoming less of a ‘canyon’ and more of a ‘gentle valley’ making it more difficult for the voltage sensing to detect. If the charger is able to monitor the temperature of the pack then it can very accurately detect the level of charge, as once the pack is full the excess energy can only convert into heat. This means that Delta-T is considered a more robust method of charge termination, and allows higher charge currents, as the possibility of overcharging is removed.

Need a charger?

Click the button related to your battery chemistry to view the range

Summary

Because FRIWO have been designing and manufacturing bespoke battery chargers for every commercially used battery chemistry for over 40 years we offer products featuring all the technologies featured in this blog, and would be delighted to help you select a charger that will keep your batteries in top working condition for as long as physically possible (until a battery is invented that lasts forever) 


CONTACT US

COMMENT ON THIS POST

SHARE THIS POST
While you're here, why not read some of our other blog posts?
We are 99% sure you'll learn something!
A group of DC connectors with USB Type-C, Magnetic connector, Barrel connector with inner pin
By Alex Chapman 23 Feb, 2024
Join us for a deep dive into the pros and cons of Direct Current (DC) connectors. have a project that requires a DC connector? Find your perfect match here!
By Ben Winstanley 06 Oct, 2021
INDEPENDENT POWER SUPPLY FOR MEDICAL EXOSKELETONS A FRIWO systems solution in practice Finally being able to walk again. ExoAtlet, the renowned medical technology company, wants to grant that exact wish to its patients with physical disabilities. The specially designed and built exoskeleton allows people who have been confined to a wheelchair to stand freely, and without assistance, for the first time since their disability – and not only stand, but walk! The “ExoAtlet II” skeleton allows the wearer to move at different speeds as well as across different types of terrain without being hindered by stairs or other obstacles.
Switchmode Power Supplies vs Linear Power Supplies
By Ben Winstanley 05 May, 2021
Switchmode Power Supplies vs Linear Power Supplies The vast majority of low voltage external power supplies sold globally these days are switching (switchmode) units, as opposed to the original Linear technology, which is only considered appropriate for certain niche markets due to it’s inability to meet required efficiency standards. In this article we will explore just some of the technical aspects & features and benefits of Switchmode topology vs Linear.
Micro USB Vs USB-C Comic Battle - Visual Created by Haredata Electronics
By Ben Winstanley 28 Jan, 2021
The micro USB connector has been the most common connector for plug top devices for the last few years, but as with everything the times are changing. This is where the Type-C USB has started to step in, with more and more pieces of tech coming with a Type-C charger rather than the old favourite. So the question is why? If the old micro USB isn’t broken then why ‘fix’ it? 
The New UKCA (UK Conformity Assessed) Marking
By Ben Winstanley 15 Dec, 2020
The UKCA (UK Conformity Assessed) marking is a new UK product marking that will be used for goods being placed on the market in Great Britain (England, Wales and Scotland). It covers most goods which previously required the CE marking.
What is MDR? The New Medical Device Regulation
By Ben Winstanley 29 Oct, 2020
What is MDR? Medical Device Regulation MDR is a new regulation issued by the European Parliament and the council of medical devices. It is replacing previous medical device directives 90/385/EEC and 93/42/EEC. The requirements of the new regulation are more complex than previously and are different per product. The vast majority of products are subject to new labelling and documentation requirements, such as; • Requirements for a unique device identification number (UDI) • Traceability of products The new requirements specified by the MDR cover each role played by differing companies on the supply chain, meaning at each step there are new responsibilities to be aware of. When does the MDR come into play? The MDR was initially due to begin the transition in May of this year but due to the global pandemic it is has been postponed to 26th May 2021. This transition deadline has to be met by all companies and suppliers by the date. What does MDR mean for power supplies?
By Ben Winstanley 27 Oct, 2020
From December 20, 2020, the IEC 62368-1 is set to take over from the IEC 60950-1 and IEC 60065 for the new standard for ICT and AV equipment. It brings together two separate standards linking terminologies and key engineering tenets, this new standard will become law and be used throughout Europe and USA. In Europe, the transition will be rapid and the expectation for all equipment to meet these new standards will be expected. Whereas, in the USA the transition will be slower starting with new submissions matching the standards and some existing products not having to be re-reviewed. Why the change? The IEC 62368-1 is a unified and smoother set of standards to follow internationally. It is here to revolutionise the approach for basic hazard safety, as new types of affordable products have emerged for use both leisurely and for business. Due to the constant changing state and technological advances blurs the lines between AV and ICT are blurred meaning the standards should begin to overlap
back to the future parody
By Ben Winstanley 24 Aug, 2020
In a best effort to reduce our carbon footprint within the UK we are aiming to ban the sale and production of diesel, petrol, hybrid, and plug-in hybrid cars. Due to this, consumers will only be able to buy vehicles that run on electricity or hydrogen. Just under 1/3 of our carbon emissions in the UK come from transport, whether that be personal or public. By removing the public’s access to cars that can produce emissions the government can control the public transport and how energy efficient that is. There are already several electric bus companies including some in our own area. The Law Since 2009 the previous government started to get the wheels turning on electric vehicles becoming the norm. However, the real impact came from the announcement of a legal ban on all non-electric or hydrogen cars being created from 2035, which had been moved forward from 2040. This does not mean you will have to get rid of your petrol car, but it does mean that any car you wish to purchase from this point will be electric
By Ben Winstanley 13 Aug, 2020
Apart from the top printing, structurally from the outside they are identical, however the internal architecture is significantly different!
More Posts
Share by: